3 tests to check the medical gas system
- Analyze the purity of medical gases
Medical gases travel long distances to reach the different points where they will be used. For this reason, testing the quality of this gas that the patient will later inhale is of the utmost importance.
Analytical controls are indicated to perform this analysis. To carry out these studies, the need to have adequate storage areas for cylinders protected against possible deterioration must also be taken into account. There must be closed circuits built solely for medical air.
- Periodically carry out the respective hydrostatic pressure tests
The cylinders in which the gases are stored can have a fairly long useful life, depending on the way in which they have been treated and handled by the person. For this reason, to check the health of the gases, it is also necessary to check the hydrostatic pressure that these cylinders have.
The ideal is to perform this type of test every five years, and if the cylinder passes the test with positive numbers, it can be used for another five years. In this regard, for Medical Gas Service, it is also important that the technical team carry out a series of hydrostatic pressure tests, which are carried out with the aim of increasing safety and thus being able to guarantee that the cylinders or tanks that contain the medicinal gases are capable of withstanding the high pressures to which they are usually subjected.
- Check connections between valves and regulators.
Generally, gas cylinders come with a valve.To detect Medical Gas Leak Detection and test the gas passage, the valves must be correctly graduated and positioned to provide safety.
These valves and regulators must be checked before they are placed on the cylinder in order to ensure that the connections match properly. Otherwise, it would indicate misuse or the use of the wrong regulator.
For Medical Gas Fittings, the technician must connect the regulator to the valve, stand next to the regulator before opening it, and watch that the safety seat does not jump when the cylinder is opened. If so, it would indicate that the gas pressure is too high, which could cause a fire.
When regulators are checked on a regular basis, it will be easier to detect the different mechanical problems that can occur before the damage is even more serious.
If when the technician checks the Custom Hose, the regulator, and the low-pressure gauge needle rises while the downflow is shut off, you know the regulator is badly damaged.
It is worth mentioning that the Medical Gas Cylinders process must be carried out only by security professionals and specialized technicians. If the personnel find a leak, they must report it immediately and stop using the cylinder.